Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does the control data get from CM16a to the amplifier and how does the PC (System Controller) communicate with the CM16a?

0
Posted

How does the control data get from CM16a to the amplifier and how does the PC (System Controller) communicate with the CM16a?

0

The data is transferred between the CM16a and the amplifier using a HD 15 DataPort cable. Monitor data goes from the amplifier to the CM16a and the control data goes from the CM16a to the amplifier. Communication between the Controller (PC) and the CM16a is accomplished via a CAT5 cable with RJ45 connections. If a switch/hub is being used, a standard straight through cable is needed. However, if the CM16a is connected directly to the PC, a cross-over cable must be used.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123