Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does the auto flush feature on the PureFlow II 50 and 100 gallon per day pump assist units work?

0
Posted

How does the auto flush feature on the PureFlow II 50 and 100 gallon per day pump assist units work?

0

Any time the incoming water pressure drops too low a pressure sensor turns on the pump to boost the pressure back up. Every time the pump turns on the flush valve opens up for about 10 seconds flushing water over the RO membrane then shuts off. The flush water goes out the waste water line.

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.