• Basic Inspection inspects one part. The results are for that part only and there is no way to compare one inspection to another. With SPC Inspection, a list of reports for scanned parts is kept for each CAD file you run. From these reports, FabriVISION can create a set of SPC data. For SPC Inspection to be valid each inspected part in the run must be examined using the same alignment method and the same dimensioned features. Therefore, when you inspect the first part in an SPC run, FabriVISION remembers the alignment and the dimensions you establish. For each subsequent part, FabriVISION will recall the same alignment method (you will be prompted to pick the same patterns) and dimensioned features. For more information, see Chapter 5: SPC Inspection.