Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does Micron validate the quality of its IBIS and HSPICE models?

hspice IBIS Micron models quality
0
Posted

How does Micron validate the quality of its IBIS and HSPICE models?

0

To validate a model to lab measurements, Micron compares several items, such as input capacitance, power and ground clamp diode characteristics, output buffer drive strength, and output buffer slew rates. New Micron models include a quality report that compares model characteristics to lab measurements and data sheet specifications.