Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does lightning or other transient spikes impact operation of an LED fixture?

0
Posted

How does lightning or other transient spikes impact operation of an LED fixture?

0

If a typical power supply is used for outdoor lighting, transients on the power line will cause instant failure. Most commercially available power supplies are tested to withstand typical indoor transients of 1000 volts. This is a minimal level needed to get past a short warranty period operation in a well protected building environment. It is grossly insufficient for outdoor applications. ALSI’s power supplies are designed to withstand transient events up to 6000 volts, in accordance with the specification ANSI / IEEE C62.41 level B3. This gives a very high probability of survival for up to 30 years in outdoor environments.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123