Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does a facility count the amount of release flammable COI within a mixture that is not a fuel with an NFPA rating of 1, 2, or 3?

0
10 Posted

How does a facility count the amount of release flammable COI within a mixture that is not a fuel with an NFPA rating of 1, 2, or 3?

0
10

If a release-flammable chemical of interest is present in a mixture in a concentration equal to or greater than one percent (1%) by weight of the mixture, and the mixture has a NFPA flammability hazard rating lower than 4 (i.e., NFPA hazard rating of 1, 2, or 3), and it is not a fuel, the facility need not count the entire weight of the mixture toward the STQ. Mixtures with a NFPA flammability hazard rating of 1, 2 or 3 are calculated by multiplying the percentage of the COI times the total weight of the mixture to see if the COI meets or exceeds the STQ. If a release-flammable COI is present in a mixture, and the concentration of the chemical is less than one percent (1%) by weight, the facility need not count the mixture in determining whether the facility possesses the STQ.