Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How do I wire two CK-20F/HWKs and one power venter with two residential gas water heaters?

0
Posted

How do I wire two CK-20F/HWKs and one power venter with two residential gas water heaters?

0

Connect the hot leg of 120-vac power supply to L1 on the CK-20F/HWK control kit, then run a wire from L1 to the common side on the gas pressure switch. Run a wire from the normally open side of gas pressure switch to the M terminal on the CK-20F/HWK. Run additional wires from L1 on CK-20F/HWK to common side on the second gas pressure switch. Run additional wire from the M terminal on CK-20F/HWK to the normally open terminal on the second gas pressure switch. Then run white wire out of power venter motor to the N terminal on the CK-20F/HWK kit to the neutral from the power source. Connect the black wire on the power venter motor to the M terminal on each control kit.