How do I use the Sunny Tripower inverters by SMA in PV*SOL ?
The Sunny Tripower inverters have 2 asymmetrical MPP trackers and there are thus a few things that need to be taken into consideration with the design. The main inverter (Input A) is saved in PV*SOLs inverter database with a reference for the inverter type. In addition, for the second array, the Tripower Extraeingang inverter (Input B) must be selected (for all models the same). Input B can bear up to 8.8 kW in a maximum of one string. This actual installed power must then be withdrawn from Input A. If you want to configure Input B with more than 2 kW, you will need to go to Databases > Inverter > Grid Connected at first, than select the inverters that match the power values correspondingly (Input A low, Input B high) and save in the database as a user-created data record using Save As. As a rule, the majority of modules should be connected to Input A and the rest of the modules to Input B (e.g. with 56 modules – 2 strings with 23 modules to Input A and 1 string with 10 modules to Inpu