Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How do I resolve B37 abends while using IEHMOVE?

abends resolve
0
0 Posted

How do I resolve B37 abends while using IEHMOVE?

0
0

If the reason for the B37 is that SYSUT1 is out of space, Wayne Mitchell suggested a solution (in September 2003 on the H390-MVS list)- add a POWER parameter to the EXEC statement: //IEHMOVE EXEC PGM=IEHMOVE,PARM=’POWER=9′ He said that a value of 9 will handle anything except SMP datasets, although he had used a value as high as 19. I can find no documentation of this parameter anywhere, at least in the manuals and books I have on hand. But the source code for IEHMOVE shows that the value can have a maximum of three digits, so you should be able to specify this and process some really large datasets with IEHMOVE.