Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How do I pick the correct air precharge pressure for my hydro-pneumatic bladder tank?

0
Posted

How do I pick the correct air precharge pressure for my hydro-pneumatic bladder tank?

0

The tank should be set approximately 2 PSI below the lowest pressure switch setting (pump cut-in pressure). For example, the air charge pressure should be set at 28 PSI for a pressure switch setting of 30 PSI minimum and 50 PSI maximum. For surge applications, the tank should be set approximately 10% to 20% below the system pressure.