How do I open data capture with the Sniffer file save type as the default option?
A. This requires installation of the RTM 1.4 patch 303 ( registered customers only) . To set the Sniffer save type option, set the pa.capturefileformat.netscout property to false in the client.properties file. This property makes sure that the Sniffer file save type option is always selected when a user opens the data capture view. Complete these steps: • Stop RTM server. • Change the directory: • Windows: RTMROOT\rtm\html • Solaris: RTMROOT/rtm/html • Edit the client.properties file. • Add pa.capturefileformat.netscout=false to the client.properties file. • Save the file. • Restart the server.