How do I model different parts of the piping system inside and outside a building for wind loads?
You will need to model the section of pipe inside the building as a different segment to the outside piping. On the main wind dialog, uncheck the option “All segments exposed to wind” and after all the wind loads have been defined, a segment dialog will appear which you can select or de-select the segments which will have wind loading applied to them.