Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How do I model different parts of the piping system inside and outside a building for wind loads?

0
Posted

How do I model different parts of the piping system inside and outside a building for wind loads?

0

You will need to model the section of pipe inside the building as a different segment to the outside piping. On the main wind dialog, uncheck the option “All segments exposed to wind” and after all the wind loads have been defined, a segment dialog will appear which you can select or de-select the segments which will have wind loading applied to them.