How do I “hook-up” to the security feature (remote alarm feature)?
The security feature of the RC2000_S and RC5000_S cabinets is easy to connect to any dedicated monitoring system (i.e. ADT, etc). The feature is normally closed and opens when the door of the cabinet is opened (thus setting off the alarm). In order for the remote alarm to function, the security option feature must have been installed with the cabinet at the time of order. Located on the interior back of the cabinet is a telephone interface connection box. Security experts can connect into the two (2) screw terminals inside of the box through the pre-drilled hole that leads into the box. • Can the RC2000_S and RC5000_S be configured to be “normally open”. Yes The circuit board is also equipped with a normally open connection. To utilize this connection, remove the circuit cover and reposition the connection from the security terminal block to pins 9 and 10 of the main terminal strip (TB1) to the small two position terminal block (TB2). • Can the RescueCase be connected to an Autodialer?