Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

HOW DO I CHANGE MY FACILITY FROM USING PLASTIC MEDIA TO AN EnviroStrip® PRODUCT?

0
Posted

HOW DO I CHANGE MY FACILITY FROM USING PLASTIC MEDIA TO AN EnviroStrip® PRODUCT?

0

• Dry Air: Compressed air should be clean and dried to a 40 degree pressure dew point • Dust Separation: A large media mesh-size range is required for Envirostrip. Change vibratory screens and/or adjust cyclones to allow media in the 12 to 100 mesh size to be returned to the storage hoppers. • Positive displacement media feed valves: allows for accurate media flow and high flow rates if needed (16+ lb/min) • 70 degree angle or incline on all storage hoppers and pressure vessels • New media make-up feeder: provides new media to system as dust/fines are removed.