Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How can I model a shut after time delay pump that has neither a check valve or control valve?

CONTROL delay model pump time valve
0
Posted

How can I model a shut after time delay pump that has neither a check valve or control valve?

0

When using “shut down after time delay” transient pump type, you must select either “control valve” or “check valve” as the Pump valve type. If you do not want a check valve or control valve, select “Control Valve” As the pump valve type and enter a large number such as 9999999 seconds, as the “Time (For Valve to Close)”.