How can I demonstrate that I have applied more restrictive criteria the first time I used ECDA (required by 195.588(b)(2)-(4) and NACE-0502-2002)?
There are a number of ways in which operators can be more restrictive during first time use of ECDA. Operators must apply more restrictive criteria in the first three phases of ECDA (i.e., pre-assessment, indirect examination and direct examination). Examples of more restrictive criteria that could be used include but are not limited to: Pre-assessment Making and/or segregating the HCA-affecting segment(s) into additional ECDA regions, which requires additional excavations Perform test holes to obtain additional data on the pipeline and its environment and soil conditions Pre-marking the pipeline to enhance data integration such as putting flags or paint dots at regular intervals (e.g., 5 ft.) all along the pipeline Indirect examination For paved areas, require boring to the subsurface soil to obtain readings Use an additional tool, three instead of two, four instead of three, etc. Establishing a severity table and apply increased severity for each tool result, such as: For CIS any rea