How can I adjust the Automatic Exposure Control in order not to affect VMD?
A. This will be set at the qualification stage. If there is slow and constant lighting change, increase the “Bg frames” in the VMD menu. That will give more time for the image background to settle. Adjust sensitivity in order to reduce FAR. Calculate the right field of view and set the right minimum object size to detect, a wide angle lens is recommended with medium to large value for minimum object size (cars, people). Make sure that the ROI is well isolated from sources of false alarms.