Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How are seals & sealing of the water circuits performed?

0
Posted

How are seals & sealing of the water circuits performed?

0

SPI standard rotary platens have two circuits. The water comes in from the fixed portion of the rotary platen (base plate) where two ¼ NTP circuits feed into one channel in the water union (center rotating shaft) of the rotary platen. It is fed into the moving portion of the platen (rotating plate) and is separated back into two ¼ NTP circuits. The circuit in the water union has the same volume to handle the capacity for the two ¼ NTP feed circuits.