How accurately do semi-permeable membrane devices measure the bioavailability of polycyclic aromatic hydrocarbons to Daphnia magna?
Semi-permeable membrane devices (SPMDs) are passive samplers that have been designed to sample the bioavailable fractions of hydrophobic organic compounds in aquatic ecosystems. This study aims at evaluating the ability for SPMD to sample polycyclic aromatic hydrocarbons (fluoranthene, pyrene and benzo[a]pyrene) that are actually bioavailable to Daphnia magna. For that purpose, the SPMD-available fraction and the bioavailable fraction to D. magna are compared in controlled media with Dissolved Organic Matters (DOMs) from various origins and at different concentrations. The presence of all but one DOM reduces the accumulation of PAHs in SPMD or in D. magna. Moreover, this comparative laboratory study shows that in 10 cases on 13, the SPMD-available fraction is close to the available fraction to D. magna. When significant differences are observed between SPMD-available and bioavailable fractions, they remain less than 50% at DOM concentrations below 10mg/l DOC, which corresponds to a max