Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

FabriVISION keeps scanning beyond the end of the part. What’s happening?

0
Posted

FabriVISION keeps scanning beyond the end of the part. What’s happening?

0

• You may want to check several things: • -Move the part further from the home-end edge of the glass and make sure it’s far enough away from any other edge. -Clean the viewing glass and calibration scale. – Wipe off any fingerprints on the fluorescent bulb. – Change the fluorescent bulb. – Check for scratches on the viewing glass. If the glass has been damaged, you may need to replace it. This is not covered under FabriVISION’s warranty. You can purchase the glass from the Globe Amerada Archetectural Glass Company (800-633-2513 or 334-875-1900) by requesting this description: • Stock number DBL CHEM-TEM 030 MS2070900 7/32-inch thick 50_ inches by 731/3 inches) ** • ** PLEASE REMOVE THE BEZELS AND ACTUALLY MEASURE THE GLASS IN THE TABLE TO ENSURE YOU ORDER THE CORRECT SIZE ** This is not a regular tempered glass. Instead, it’s chemically hardened and laminated. Make sure the glass is without trademark or logo, free of scratches.