Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does the SignalReference field in the Measurement table need to be unique?

field measurement Table
0
Posted

Does the SignalReference field in the Measurement table need to be unique?

0

Like device acronyms, signal reference values must be unique (the database definitions should enforce this constraint). The signal reference creates an association between a unique individual signal (i.e., a measurement) and a channel value within a parsed frame of phasor data from a specific PMU.