Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does the photodiode come with a measuring device (voltmeter)? If not, what measuring device is recommended?

0
Posted

Does the photodiode come with a measuring device (voltmeter)? If not, what measuring device is recommended?

0

NIST does not provide a measuring device. Most customers use an current-to-voltage convertor (op-amp), either home-built or commercial. You will want to measure the current from the photodiode, and there are several vendors who can supply equipment to do this. However, do NOT use a DMM to measure the current from a photodiode. Because most DMMs measure current by measuring the voltage drop across a resistor, you will not be measuring the current from the photodiode correctly. For information about building electronics for your detector, see the following publications by George Eppeldauer. NIST Technical Note 1438 – Optical Radiation Measurement with Selected Detectors and Matched Electronic Circuits Between 200 nm and 20 m (13.9 MB) NIST Technical Note 1621 – Optical Radiation Measurements Based on Detector Standards (8.0 MB) Commercial devices vary by price and quality. Make sure to consider stability. An amp meter may have good specifications, such as low noise, high dynamic range, e

0

NIST does not provide a measuring device. Most customers use an current-to-voltage convertor (op-amp), either home-built or commercial. You will want to measure the current from the photodiode, and there are several vendors who can supply equipment to do this. However, do NOT use a DMM to measure the current from a photodiode. Because most DMMs measure current by measuring the voltage drop across a resistor, you will not be measuring the current from the photodiode correctly. For information about building electronics for your detector, see the following publications by NIST Staff, George Eppeldauer. NIST Technical Note 1438 – Optical Radiation Measurement with Selected Detectors and Matched Electronic Circuits Between 200 nm and 20 m (13.9 MB) NIST Technical Note 1621 – Optical Radiation Measurements Based on Detector Standards (8.0 MB) Commercial devices vary by price and quality. Make sure to consider stability. An amp meter may have good specifications, such as low noise, high dyna

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123