Does the Pana40 Plus provide a nudging relay?
Yes, the Pana40 Plus MKII (Model 842) controller provides three programmable output relays which may be configured to provide a nudging signal. Note that the door operator must be able to support this function and be able to close the doors under reduced speed and torque. If the detectors have been blocked for more then a preset time i.e. between 10-70s adjustable, the main door re-open relay is energized (door close signal) and the second relay is de-energized (slow speed signal). The third relay is usually configured to follow the second relay and may be connected to an external alarm.