Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does the kerosene Aga or Rayburn cooker require servicing between the recommended 6 month service?

0
Posted

Does the kerosene Aga or Rayburn cooker require servicing between the recommended 6 month service?

0

This type of cooker running on kerosene, requires both fuel quality, and quality of cooker maintenance to be of the highest order. A Char value test which is a good indicator of fuel combustion quality in this application is carried out at the refinery, and will ensure that the fuel not only meets the BS2869 class C2 standard, but is significantly lower. BS max Char Value is 20mg/kg whereas Shell’s typical Char Value is 4-10mg/ kg. If there are concerns about fuel quality, then Shell Technical Services should be contacted. They, may require a customer sample to be analysed, to confirm its quality.