Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does SCRA comply with the thickness data management practices recommended in API 510 & 570?

0
Posted

Does SCRA comply with the thickness data management practices recommended in API 510 & 570?

0

SCRA complies fully with API 510 & API 570 language for statistical analysis of thickness data, which requires that statistical predictions accurately reflect the actual equipment conditions. Since SCRA develops a best-fitting model for the corrosion behavior in each piece of equipment and properly analyzes localized/accelerated corrosion, the remaining life estimates and re-inspection schedules are truly representative of the equipment condition. SCRA runs the statistical and straight-line API 510/570 calculations simultaneously. By default, the more conservative re-inspection schedule is used; however, users may select the SCRA statistical schedule after reviewing the analysis report.