Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does L-Edit extract parasitics as distributed or lumped?

0
Posted

Does L-Edit extract parasitics as distributed or lumped?

0

Currently, L-Edit extracts interconnect parasitic as a lumped capacitance. The capacitance is calculated from the interconnect layer to the substrate and does not take into consideration shielding effects of intersecting layers. With HiPer PX product (schedule to release in 2008) you can extract distributed nature of parasitic resistance and capacitance of IC interconnects.