Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does a service unit have to be fitted with a manual on-off valve?

fitted manual on-off service valve
0
Posted

Does a service unit have to be fitted with a manual on-off valve?

0

According to DIN 24558 point 8.1.2, all pneumatic systems must have an on-off valve in the main supply line. It must be possible for this valve to be secured against unintentional and unauthorised operation in the closed position (system vented) (please also refer to UVV 10.0). However, this does not necessarily mean that the manual on-off valve must directly be part of the service unit, as may be implied here.