Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Do the opening forces comply with the requirements of Approved Document M?

0
Posted

Do the opening forces comply with the requirements of Approved Document M?

0

The maximum opening forces referred to within Approved Document ‘M’ are not exceeded by R100 Perko-Powermatic on doors of a minimum width of 826mm, whilst still maintaining compliance with BS EN 1154. As Approved Document M applies to the entire doorset when fitted, consideration must be given to the door width, other installed hardware and differential air pressures within the building to ensure Perko Powermatic® meets the recommendations in situ.