Do tantalum and titanium cups show similar results in revision hip arthroplasty?
Porous surfaces are intended to enhance osteointegration of cementless implants. Tantalum has been introduced in an effort to enhance osseointegration potential of uncemented components. We therefore compared the clinical outcome of acetabular components with two different porous surfaces. We retrospectively reviewed 283 patients (295 hips) who underwent cementless revision hip arthroplasty with either an HA-coated titanium cup (207 patients, 214 hips) or porous tantalum cup (79 patients, 81 hips). The minimum followup was 24 months in both groups (titanium: average 51.8 months, range, 24-98 months; tantalum: average, 35.4 months, range, 24-63 months). The titanium and tantalum groups had a mechanical failure rate (clinical plus radiographic) of 8% and 6%, respectively. In hips with minor bone deficiency (type 1, 2A, 2B using the classification of Paprosky et al.), 6% of titanium cups and 4% of tantalum cups failed. In hips with major bone deficiency (type 2C, 3), 24% of titanium cups