Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Do semiquantitative amniotic fluid indexes reflect actual volume?

0
Posted

Do semiquantitative amniotic fluid indexes reflect actual volume?

0

OBJECTIVE: Our objective was to determine how well semiquantitative ultrasonographic measures of amniotic fluid, i.e., maximal amniotic fluid vertical pocket and amniotic fluid index, reflect actual amniotic fluid volumes in 50 near-term patients whose amniotic fluid volume estimates were normal by visual inspection. STUDY DESIGN: Before amniocentesis for fetal lung maturity, each patient had visual amniotic fluid volume estimates, maximal amniotic fluid vertical pocket, and amniotic fluid index performed by the same examiner, and then each received intraamniotic injection of a 10% paraaminohippurate solution. Amniotic fluid volume was quantitated by spectrophotometric assay of paraaminohippurate concentration. Oligohydramnios and polyhydramnios were defined as < 300 and > 2000 ml, respectively. RESULTS: Quantitative amniotic fluid volume was positively related to both amniotic fluid index and maximal amniotic fluid vertical pocket (r = 0.75 and 0.60, respectively). True-positive rates