Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Do I still require a vapour barrier with NUDURA?

barrier nudura require Vapour
0
10 Posted

Do I still require a vapour barrier with NUDURA?

0
10

According the standard ASTM E 96, to qualify as a vapour barrier, a material must not exceed 45 ng/Paּsּm².This unit denotes the ‘permeance’ of the material, meaning how much moisture per force applied (air pressure), in a second over a square area. Our EPS foam has a permeance value of 36 ng/Paּsּm²,therefore the NUDURA Type II EPS qualifies as a vapour barrier. Better recognize.