Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can the VX-VEB160R2 be installed over CAT5e/RJ-45?

Cat5e installed rj-45
0
Posted

Can the VX-VEB160R2 be installed over CAT5e/RJ-45?

0

Yes and no. The VX-VEB160R2 utilizes a single pair of copper to extend Ethernet through CAT3/ RJ-11. If you are familiar with crimping modular connectors, you can break out a pair of copper from the CAT5e cable and re-crimp the ends to RJ-11 on both ends. You may also purchase an RJ-45 to RJ-11 coupler at your local electronics store as well. The VX-VEB160R2’s are not linking after we have deployed/installed the units. I have already power cycled both units and re-crimped my cables. There are many variables that can affect the link between the Ethernet Extenders. Some common problems can be the wiring between the units such as a cut or open short on the line, coiled line, equipment failure, noise on the line or incorrect/loose wiring on the RJ-11 head. To verify cable or equipment failure, simply connect both units side by side on a table and verify if they link with the correct ports using the provided RJ-11 cable. If they do link, you may have faulty wiring. If they are unable to lin