Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can the same CUADDR be used across different paths or channel path identifiers (CHPIDs) in an ESCON Multiple Image Facility (EMIF) scenario?

0
Posted

Can the same CUADDR be used across different paths or channel path identifiers (CHPIDs) in an ESCON Multiple Image Facility (EMIF) scenario?

0

A. Yes. Q. There is no documentation or recommendation on the second value in the UNITADD parameter in the IOCP GEN. How many devices should be coded for each path? Are there any recommendations? Is there a minimum requirement? A. In the past, most people would use a minimum of 16. The CIP minimum is 2. If you only have one TCP/IP stack per partition, two should be adequate. However, it actually makes sense to define more than two subchannels, if you want to use these: • Second TCP/IP address space for: • Testing new versions or other products. • Security. • Performance. • Something else, like Interlink DECnet.