Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can the Pro-Tec Mod system be used in a 3-sided configuration?

0
10 Posted

Can the Pro-Tec Mod system be used in a 3-sided configuration?

0
10

• A Pro-Tec Equipment’s Mod Series Aluminum Trench Shields can be used in a three-sided manner, as long as the following requirements are met: For the third side of the system, a minimum of two struts/spreaders or panels must be used, not exceeding 36″ of vertical clearance. If the struts/spreaders or panels are removed on the third side, the engineering for such a system is the responsibility of others, unless site specific engineering is supplied by Pro-Tec Equipment.