Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can the MAX1464 be used to measure the RTDs or K-type thermocouples?

0
Posted

Can the MAX1464 be used to measure the RTDs or K-type thermocouples?

0

A. Yes. The user must always ensure that the voltage levels at INM and INP are above VSS and below VDD. If extra gain is necessary, the op amps in the DOP can be used to implement an analog gain stage, which will result in converting a differential signal to a single-ended signal. The output of this gain stage can then be fed into the ADC for conversion, or the op-amp output can be directly converted using one of the ADC-loopback conversion modes.