Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can the drain line be located above the softener?

drain line located softener
0
Posted

Can the drain line be located above the softener?

0

As long as the water pressure at the softener is not less than 40 PSI and the run of the drain line does not exceed 15″, your discharge line may be elevated up to 6″ above the system. For each additional 10 PSI of water supply the line can be elevated an additional 2″.