Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can Speedfit Pipe be buried in the floor screed?

floor pipe screed speedfit
0
Posted

Can Speedfit Pipe be buried in the floor screed?

0

The Building Regulations state that pipe laid in screed must be removable. Speedfit provide a conduit pipe through which the Speedfit Pipe can be laid. If the Speedfit Pipe needs to be replaced, it can be disconnected at each end of the conduit and then pulled out. The installation of fittings in screed should be avoided. Where it is deemed necessary, they should be installed in an access box with a removable lid. Conduit pipe is supplied with an outside diameter of 24mm for use with 15mm pipe and an outside diameter of 30mm for use with 22mm pipe. Both sizes are available in lengths of 25 metres or 50 metres.