Can Ringers lactate be used safely with blood transfusions?
GROUND: Blood bank recommendations specify that Ringer’s lactate solution (LR) should be avoided while transfusing blood. However, there are few studies either evaluating or quantifying increased coagulation during rapid infusion of LR and blood. DESIGN AND METHODS: Whole blood (WB, n = 25) and packed red blood cells (PRBC, n = 26) were rapidly admixed with normal saline (NS), Lactate solution and LR with 1 g (LR-1), 2 g (LR-2), and 5 g (LR-5) CaCl2/L solutions for assessment of infusion time, filter weight, and clot formation. RESULTS: No significant differences in infusion time or filter weight using WB or PRBC with NS or LR were seen. No significant difference in clot formation between NS and LR with WB or PRBC was found, but the presence of visible clot was increased in the LR-5 group (P = 0.013, WB, and P = 0.002, PRBC). CONCLUSION: A comparison of LR and NS with rapid infusion rates of blood showed no significant difference between infusion time, filter weight and clot formation.