Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can PV*SOL calculate systems with tracking?

CALCULATE pv*sol SYSTEMS
0
Posted

Can PV*SOL calculate systems with tracking?

0

Yes. In the Technical Data dialogue, under PV Array > Orientation, you can select between single and dual axis tracking. With single axis tracking, an azimuth of -90 to 90 (i.e. for the northern hemisphere: from east to west) is allowed for with a vertical rotation axis. Dual axis tracking calculates the situation with movement of both rotation axes. In both cases, the technical limits of the tracking system are not observed. This means that if the tracking system can only be rotated up to a certain angle, this is not taken into consideration by the software.