Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I vent multiple heaters with one SideShot?

Heaters sideshot vent
0
Posted

Can I vent multiple heaters with one SideShot?

0

Yes. You will need to add an MAC1E interlock control to support the second appliance. It will interface with the UC1 control allowing you to interlock two individual appliances with one SideShot. Both appliances will need to share a common manifold or vent connector prior to the inlet of the SideShot. The total equivalent length of allowable pipe for a SideShot is fifty feet. Each elbow must be counted as ten feet. So the actual linear length of vent pipe is usually less than fifty feet. There is also a BTU/hr input limit that may not be exceeded. You can check the sizing table on-line or you can contact Tjernlund Products for assistance, 1-800-255-4208.