Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I use Traditional NI-DAQ (Legacy) and NI-DAQmx at the same time?

0
Posted

Can I use Traditional NI-DAQ (Legacy) and NI-DAQmx at the same time?

0

You can use Traditional NI-DAQ (Legacy) and NI-DAQmx at the same time if you have two DAQ devices and one of them is using Traditional NI-DAQ (Legacy) and the other NI-DAQmx. If you only have one DAQ device, you can still use both Traditional NI-DAQ (Legacy) and NI-DAQmx but only in sequence – not at the same time. You need to reset your device to switch between Traditional NI-DAQ (Legacy) and the NI-DAQmx driver as part of the sequence. In LabVIEW, use the Device Reset VI at the end of Traditional NI-DAQ (Legacy) sequence and the DAQmx Reset Device VI at the end of your NI-DAQmx sequence. You still need to create a Traditional NI-DAQ (Legacy) virtual channel and an NI-DAQmx Task for use with each driver respectively.