Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I use the FMEDA numbers directly off the report when doing PFD calculations for Prior-Use sensors?

0
Posted

Can I use the FMEDA numbers directly off the report when doing PFD calculations for Prior-Use sensors?

0

Prior-Use requires the end user to calculate the PFD (inverse of the MTBF) for a given sensor in a given application. The PFD numbers in a FMEDA are not meant to be used directly. They are there as a conservative estimate for you to use to validate your MTBF calculation.