Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I increase the default timeout value for the sender adapter?

0
Posted

Can I increase the default timeout value for the sender adapter?

0

Yes. The default timeout value for synchronous calls is 5 minutes. You can increase this value by setting parameter XI.Timeout in the module parameter table of the SOAP adapter. The value must be given in milliseconds. For example, value 600000 represents the timeout value of 10 minutes. This parameter is not recognized in systems prior to SP13.