Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I configure DLSw+ on two MSFC2 cards in the same chassis?

0
Posted

Can I configure DLSw+ on two MSFC2 cards in the same chassis?

0

A. DLSw+ works on an MSFC; however, no official tests have been performed with two MSFC2s in the same chassis. DLSw+ code has no way to identify that the two MSFC2s are in the same chassis, and has no supporting code for anything like this. More importantly, DLSw+ Ethernet Redundancy is designed for the remote end, not for the central site. Ethernet Redundancy still assumes a Token Ring is on the central location.