Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can an imported m/c designed for 60Hz supply be fed through an AC Drive?

0
Posted

Can an imported m/c designed for 60Hz supply be fed through an AC Drive?

0

Yes only for single motor load. But No for Non-motor loads because output wave shape is a chopped DC and not AC. No for multi motor m/c as well because switching on & off the motor on a operative system with contactors at the output calls for sizing the AC Drive so that it is capable of handling the starting current (5-6 times) of the incoming motor.