Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can a Pitot tube be used with the DP-CALC?

dp-calc pitot tube Used
0
Posted

Can a Pitot tube be used with the DP-CALC?

0

The DP-CALC can be connected to a Pitot tube. In velocity mode, the DP-CALC will read velocities from 250 to 15,500 ft/min (1.27 m/s to 78.7 m/s). Measuring velocities below 1000 ft/min (5.08 m/s) is not recommended. The Pitot tube is most accurate at velocities above 2000 ft/min (10.16 m/s).