Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can a parity module be used in a system that is not designed to use parity?

designed module parity system Used
0
Posted

Can a parity module be used in a system that is not designed to use parity?

0

Micron’s modules are manufactured to be hardware-compatible with both parity and non-parity systems. Par_in (parity in) and the high order address signals have a weak (100K-ohm) pull-down resistor to stabilize the inputs from oscillating around the switch point. Err_out (parity error out) is an open drain and should be left as a true no connect unless used in a parity system. The SPD data on a parity module does reflect parity. In rare occasions, the firmware or BIOS of a non-parity system will err on the parity bit in the SPD. For this reason, the system designer should ensure that the firmware of the non-parity system expects or ignores this portion of the SPD data.