Can a low micron external canister filter be added to maintain bath clarity and minimize solids accumulation?
A. We have tried a 200 micron filter but the maintenance became a problem. The 500 micron has become the customer’s choice. Q. Even though the liquid is screened via a 500 mesh, there will still be fines and a gradual contamination of the liquid which would need to be removed after repeated use. How does one go about either pumping the accumulated solids from the container bottom or removing the liquid for replacement? A. In the 5.5 gallon purifier we have a 140 ounce section to hold sludge/grit and to date no one has had to empty it. The process is to remove the thumb screws on the Purifier Vessel and then lift the stainless steel sink off and remove the purifier. There are a few screws that hold the bottom plate and once removed the sludge/grit can be disposed.
Related Questions