Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can 90-degree bends be used on vertical flue systems?

bends flue SYSTEMS Used vertical
0
Posted

Can 90-degree bends be used on vertical flue systems?

0

Yes, On our condensing boilers you can fit 90 degree bends to a vertical Flue systems. Note: A 90° bend is equivalent to 1.3 m length of Flue. If it is necessary to use a 90° bend in the vertical Flue, ensure the Flue above it is sloped towards the boiler to ensure that all condensate is allowed to drain from the Flue. The slope must be a minimum of 25 – 30 mm per metre.