Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Are there particular instructions for ATEX version electric pumps (explosion proof)?

0
Posted

Are there particular instructions for ATEX version electric pumps (explosion proof)?

0

1 Only authorized Caprari workshop technicians may work on the cable clamps or open the motor casing. 2 8.3. The operative characteristics of these machines must comply with the features indicated on the data plate and in the enclosed EX certificate. 3 The minimum head is at the top of the electric motor for machines operating in S1 service mode and above the pump casing for electric pumps operating in S3 jogging mode (comply with the degree of intermittence indicated on the electric pump data plate for each motor power rating). 4 It is obligatory to connect the thermal probes to the control equipment of the electric pump. Activation of the thermal probe must shut off the power supplied to the electric pump. Resetting must not be automatic. It must only occur after a qualified technician has inspected the machine. 5 It is forbidden to modify the machines or replace parts of the electric motors. Users are only allowed to replace components of the wet part (numbered L1 to L19 of the Sect

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123